No thanks! I would like to know more about CHROMacademy

 Over 3000 E-Learning topics / 5000 Articles & Applications
 
The Why, What, and How of Headspace GC

The first question to ask is, why would headspace GC be a good sampling technique? 

Headspace sampling is excellent for the qualitative or quantitative analysis of volatile species in samples that can be efficiently partitioned into the headspace gas volume from either a liquid or solid matrix.  It is also a good technique for the analysis of samples where the entire sample should not be injected into the GC instrument (i.e. dirty samples).  Headspace sampling is also particularly amenable to the analysis of trace levels of analytes. 

Typical examples of headspace analyses include:

  • Volatile Organic Compounds (VOC) from wastewater and contaminated land samples
  • Residual solvents in packaging and pharmaceuticals
  • Blood alcohol and toxicology screening
  • Aroma components from food and beverages
  • Diagnostic gas analysis from oils

Secondly, what sample and solvent types can be used for headspace GC?

Headspace GC is amenable to the analysis of both liquids and solids.

 


 

Liquids

Viscous liquids are particularly appropriate for headspace analysis.  Furthermore, liquids which contain high boiling or insoluble components, for example, blood, paint, or adhesives, are excellent candidates for headspace analysis.

Samples in water can also be excellent candidates.  Although modern capillary GC columns are much more tolerant to exposure to water there is still the problem of backflash and subsequent sample carryover when using split or splitless injection modes due to the high expansion coefficient of water.  This will result from the solvent vapor expanding to a volume which is larger than the liner and spilling over the top and into the inlet lines (Figure 1), subsequent injections will then wash these sample components back into the liner and onto the column resulting in ghost peaks.

Content on this page requires a newer version of Adobe Flash Player.

Get Adobe Flash player

Figure 1: Backflash

 
 
 

CHROMacademy Lite Membership is FREE and it only takes two minutes to register.

With a Lite Membership you are given access to:
  • this month's webcast & tutorial
  • selected eLearning modules
  • featured CHROMacademy Content
  • the CHROMacademy forum

Register here »

Test drive CHROMacademy Check out more
great content available FREE to our Lite members »

 
 


Solids

If a solid is completely insoluble in any solvent then headspace analysis may be the best option to access the analytes of interest.

If a sample is to be dissolved in a solvent, what solvents are appropriate?

 

CHROMacademy Forum


Solvents

The solvent chosen must firstly completely dissolve the sample and analytes of interest.  An excellent solvent choice is water due to ease of handling and the fact that it is non-toxic.  If a sample is insoluble in water an organic solvent may be required, in which case, both dimethyl sulfoxide (DMSO) and dimethylformamide (DMF) are commonly used.1  Both of these solvents are suitable as they can solubilize a large range of samples, have low volatility, and a high boiling point.  If a sample is soluble in both DMF and DMSO it is preferable to use DMSO as it is less volatile, has a higher boiling point and is less toxic (Figure 2).  Applications using solvents such as dimethylacetamide (DMA), N-methyl-2-pyrrolidone (NMP), ionic liquids (e.g. 1-butyl-3-methylimidazolium hexafluorophosphate, [BMIM][PF6]) have also been reported.1-3  The use of mixed diluent systems (i.e. H2O/DMSO mixtures) have also been studied and shown to affect response.4

Solvents suitable for GC headspace analysis

Figure 2: Solvents suitable for GC headspace analysis.


 

Finally, how does headspace analysis work? 

The volatile analytes are evolved into the headspace by heating the sample at a fixed temperature and for a fixed length of time in a vial of known volume (Figure 3).  Headspace analysis is an equilibrium technique and not all of the analyte will evolve into the headspace gas volume.  Therefore, reproducibility of sample preparation is important with heating, agitation rate, and the ratio of the sample volume or weight to the headspace gas volume being critical for optimum, reproducible results.   

The headspace gas can be sampled manually using a heated gas tight syringe (to avoid condensation) or by using an automated system employing a heated gas loop which transfers the sample to the GC column via a heated transfer line.  In each case a split/splitless injector is used to facilitate gas sample introduction.

The interactive diagram in Figure 3 »
details the process of headspace sampling.

 

 


 

 

References

  1. Karthikeyan, K.; Arularasu, G. T.; Devaraj, P.; Pillai, K. C. Sci Pharm. 2010, 78, 835.
  2. Hollender, E.; Hammersley, E. W. Chromatography Today 2011, 30.
  3. Liu, F. –H.; Jiang, Y. J. Chromatogr. A. 2007, 1167, 116.
  4. Kott, L.; Chen, H. M. Pharmaceutical Technology 2010, 5, 76.

 

You may also like:

 

Content on this page requires a newer version of Adobe Flash Player.

Get Adobe Flash player

Figure 3: Headspace Sampling

 

loading data
loading data
loading data
loading data
loading data

group  subsCHROMacademy can deliver to corporate clients on a multi-user subscription basis.
Served up from secure servers to the corporate intranet or individual desktops.

  • Microsite - your own learning site powered by CHROMacademy
  • Your Landing Pages -with your logo and branding
  • Customized Assessments - Based on content agreed upon Certificate of Completion
  • Certification Programs - Offer your learners a goal to strive towards
  • LMS : Connect - Our Learning Management System is S.C.O.R.M. compliant and will connect to your system
  • Engagement Package - E-newsletter stimulation program derived from your content and ours
  • Full archive of Essential Guide webcasts & tutorials
  • 1000’s of eLearning topics - HPLC / GC / Sample Prep / Mass Spec
  • Ask the Expert - our experts will answer your chromatography questions within 24 hrs.
  • Assessments - test your knowledge
  • Application notes & LCGC articles
  • Troubleshooting and virtual lab tools

Request a quote

 

 Home | About UsContact Us | SubscribeTerms and Conditions | Advertise | Privacy Policy 

loading data

loading data

loading data

 

loading data


loading data